Upgrade drive firmware with controlflash software, Before you begin, Appendix b – Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual
Page 143: Upgrade the kinetix 350 drive firmware, Appendix

Rockwell Automation Publication 2097-UM002C-EN-P - December 2013
143
Appendix
B
Upgrade the Kinetix 350 Drive Firmware
Upgrade Drive Firmware
with ControlFLASH Software
Upgrading axis module firmware by using ControlFLASH software involves
configuring your Logix5000 communication, selecting the drive to upgrade, and
upgrading the firmware.
Before You Begin
You need the following software and information before you begin.
Table 67 - Kinetix 350 System Requirements
Topic
Page
Upgrade Drive Firmware with ControlFLASH Software
Description
Cat. No.
Firmware Revision
RSLogix 5000 software
9324-RLD300NE
20.x or later
RSLinx® software
2.58 or later
ControlFLASH firmware upgrade kit
(1)
(1) Download the ControlFLASH kit from
Support at (440) 646-5800 for assistance.
For more ControlFLASH information (not drive specific), refer to the ControlFLASH Firmware Upgrade Kit Quick Start, publication
.
8.00.017 or later
Catalog numbers of the targeted Kinetix 350 drive you want to upgrade.
Network path to the targeted Kinetix 350 drive module you want to upgrade.
IMPORTANT
Input power or back-up power must be present at IPD or BP connector prior to
upgrading your target drive.
ATTENTION: To avoid personal injury or damage to equipment during the
firmware upgrade due to unpredictable motor activity, do not apply three-
phase AC.