Certification, Important safety considerations, Chapter 6 – Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual
Page 101: Kinetix 350 drive safe torque-off feature, Chapter
Rockwell Automation Publication 2097-UM002C-EN-P - December 2013
101
Chapter
6
Kinetix 350 Drive Safe Torque-off Feature
Certification
The safe torque-off circuit is type-approved and certified for use in safety
applications up to and including ISO 13849-1 performance level d (PLd) safety
category 3.
The TÜV Rheinland group has approved the Kinetix 350 drives for use in safety-
related applications up to ISO 13849-1 performance level d (PLd) safety
category 3, in which the de-energized state is considered to be the safe state. All of
the examples related to I/O included in this manual are based on achieving de-
energization as the safe state for typical machine safety systems.
Important Safety Considerations
The system user is responsible for the following:
• Validation of any sensors or actuators connected to the drive system
• Completing a machine-level risk assessment
• Certification of the machine to the desired ISO 13849-1 performance
level
• Project management and proof testing
• Programming the application software and the device configurations in
accordance with the information in this safety reference manual and the
drive product manual
Topic
Page
Safe Torque-off Connector Data
Wiring Your Safe Torque-off Circuit
Kinetix 350 Drive Safe Torque-off Feature
Kinetix 350 Drive Safe Torque-off Wiring Diagrams