Feedback and i/o cable connections, Motor feedback, Cables for specific motor/feedback combinations – Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual
Page 71
Rockwell Automation Publication 2097-UM002C-EN-P - December 2013
71
Connect the Kinetix 350 Drive System Chapter 4
Feedback and I/O Cable
Connections
Factory made cables with premolded connectors are designed to minimize EMI
and are recommended over hand-built cables to improve system performance.
However, other options are available for building your own feedback and I/O
cables.
Table 30 - Options for Connecting Motor Feedback and I/O
Table 31 - Motor Feedback Cables for Specific Motor/Feedback Combinations
Connection Option
Cat. No.
Cable
By Using This Type of Cable
Premolded connectors
N/A
Motor feedback
Refer to the table below for the premolded motor feedback
cable available for your motor.
Low-profile connector
2090-K2CK-D15M
Motor feedback
Refer to the table below for the flying-lead cable available
for your motor.
I/O Terminal Block
2097-TB1
I/O interface
User-supplied flying-lead cable.
Motor Cat. No.
Feedback Type
Feedback Cable
Premolded
Flying-lead
MPL-A/B15xxx-V/Ex4xAA,
MPL-A/B2xxx-V/Ex4xAA
High-resolution encoder
N/A
2090-XXNFMF-Sxx (standard)
2090-CFBM4DF-CDAFxx (continuous-
flex)
MPL-A/B15xxx-Hx4xAA,
MPL-A/B2xxx-Hx4xAA
Incremental encoder
MPL-A/B3xxx-Hx7xAA,
MPL-A/B4xxx-Hx7xAA,
MPL-A/B45xxx-Hx7xAA
N/A
2090-XXNFMF-Sxx (standard)
2090-CFBM7DF-CDAFxx
(1)
(continuous-
flex)
MPL-A/B3xxx-M/Sx7xAA,
MPL-A/B4xxx-M/Sx7xAA,
MPL-A/B45xxx-M/Sx7xAA
High-resolution encoder
2090-CFBM7DD-CEAAxx
(1)
(standard)
2090-CFBM7DD-CEAFxx
(1)
(continuous-
flex)
2090-CFBM7DF-CEAAxx
(1)
(standard)
2090-CFBM7DF-CEAFxx
(1)
(continuous-
flex)
MPM-A/Bxxxxx-M/S
High-resolution encoder
MPF-A/Bxxxx-M/S
MPAR-A/B3xxxx
MPAI-A/Bxxxx
MPS-A/Bxxxx-M/S
N/A
2090-XXNFMF-Sxx (standard)
2090-CFBM4DF-CDAFxx (continuous-
flex)
MPAS-A/Bxxxx-V/A
MPAR-A/B1xxxx,
MPAR-A/B2xxxx
TLY-Axxxx-B
High-resolution encoder
2090-CFBM6DD-CCAAxx (standard)
2090-CFBM6DF-CBAAxx (standard)
TLAR-Axxxxx
TLY-Axxxx-H
Incremental encoder
(1) You must remove the motor-side o-ring when you are using 2090-CPxM7DF-xxAxx cables.