Troubleshoot the Kinetix 350 Drive Chapter 7

Status Indicators

Table 50 - Drive Status Indicator

Table 51 - Axis Status Indicator

Status

Description

Off

No power. Apply power.

Alternating green/red

Self-test (power-up diagnostics). Wait for steady green.

Flashing green

Standby (device not configured). Wait for steady green.

Steady green

Normal operation, no faults.

Flashing red

Minor fault (recoverable). Refer to four-digit fault message.

Steady red

Major fault (non-recoverable). Refer to four-digit fault message.

Status

Description

Off

Off

Flash red/green

Self test

Off

Initialization - bus not up

Flashing green

Initialization - bus up

Off

Shutdown - bus not up

Flashing amber

(1)

(1) The axis and the drive define minor fault conditions. While a minor fault does not affect the drive status indicator, it does affect the

axis status indicator. When a minor fault condition is detected, a normally solid green status indicator indication changes to
alternating red-green-red-green, a normally flashing green status indicator indication changes to alternating red-off-green-off,
and a normally flashing amber indications changes to red-off-amber-off.

Shutdown - bus up

Off

Pre-charge - bus not up

Flashing amber

(1)

Start inhibit

Flashing green

(1)

(2)

(2) The drive also defines alarm conditions. When an alarm condition is detected, a normally solid green status indicator indication

changes to alternating amber-green-amber green while a normally flashing green status indicator indication changes to
alternating amber-off-green-off.

Stopped

Solid green

(1)

(2)

Stopping

Starting

Running

Testing

Flashing red

Aborting

Major faulted

Solid red

Aborting

Major faulted