beautypg.com

Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual

Page 51

background image

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

51

Programming and Parameters

Chapter 1

UTILIT

Y

Di

ag

n

os

ti

cs

229 [Alarm 1 @ Fault]

Captures and displays [Drive Alarm 1] at the time of the last
fault.

Read Only

211
224

230

230 [Alarm 2 @ Fault]

Captures and displays [Drive Alarm 2] at the time of the last
fault.

Read Only

212
224

230

234
236

[Testpoint 1 Sel]
[Testpoint 2 Sel]

Selects the function whose value is displayed
value in [Testpoint x Data].
These are internal values that are not accessible
through parameters.
See

Testpoint C odes and Functions on page 96

for a listing of available codes and functions.

Default:

Min/Max:
Units:

499

0/65535
1

235
237

[Testpoint 1 Data]
[Testpoint 2 Data]

The present value of the function selected in
[Testpoint x Sel].

Default:

Min/Max:
Units:

Read Only

–/+2147483648
1

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 16

for symbol descriptions

Values

Rela

ted

0

0

0

0

0

0

x

0

0

0

0

0

0

0

0

0

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 = Condition True

0 = Condition False
x = Reserved

Bit #

Pr

echr

g A

ct

v

UnderV

oltage

Po

wer L

oss

Str A

t P

wrUp

Anlg in L

oss

In

tDBRes OH

Dr

v OL L

vl 1

Dr

v OL L

vl 2

Dec

el Inhibt

W

aking

Mot

or T

herm

In PhaseL

oss

Load L

oss

Gr

ound W

arn

Brk Slipped

0

0

x

0

0

0

0

0

x

x

x

x

x

x

x

x

26

16

17

18

19

20

21

22

23

24

25

27

28

29

30

31

1 = Condition True

0 = Condition False
x = Reserved

Bit #

Adj V

olt

Ref

Pr

of S

etHome

PT

C HW

Ac

tiv

e Cn

vtr

(1)

(1)

Firmware 6.002 and later.

(2)

Firmware 9.001 and later.

DPI P1 L

oss

(2)

DPI P2 L

oss

(2)

DPI P3 L

oss

(2)

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 = Condition True

0 = Condition False
x = Reserved

Bit #

DigIn Cflc

tA

DigIn Cflc

tB

DigIn Cflc

tC

Bipolr Cflc

t

Mtr

Typ Cflc

t

NP Hz Cflc

t

MaxF

rq Cflc

t

VHz NegSlope

IR V

lts

Rang

FlxAmps R

ang

SpdRef Cflc

t

Ixo V

lt

Rang

Sleep C

onfig

TB Ref Cflc

t

PT

C C

onflic

t

Brk Slipped

0

0

0

0

x

x

x

x

x

x

x

x

x

x

x

x

26

16

17

18

19

20

21

22

23

24

25

27

28

29

30

31

1 = Condition True

0 = Condition False
x = Reserved

Bit #

TrqP

rv Cflc

t

Pr

ofStpCflc

t

UserS

etCflc

t

PICfgCflc

t