If using a HIM with a numeric keypad, press the ALT key and the +/– key to
access the parameter by typing its number.
Option
Description
Drive Identity
Add text to identify the drive.
Change Password
Enable/disable or modify the password.
User Dspy Lines
Select the display, parameter, scale and text for the User Display. The User Display is
two lines of user-defined data that appears when the HIM is not being used for
programming.
User Dspy Time
Set the wait time for the User Display or enable/disable it.
User Dspy Video
Select Reverse or Normal for the Frequency and User Display lines.
Reset User Dspy
Return all the options for the User Display to factory default values.
Step
Example Displays
1. In the Main Menu, press the
or
key to
scroll to “Parameter.”
2. Press the
(Enter) key. “FGP File” appears on the
top line and the first three files appear below it.
3. Press the
or
key to scroll through the
files.
4. Press the
(Enter) key to select a file. The groups
in the file are displayed under it.
5. Repeat steps 3 and 4 to select a group and then a
parameter. The parameter value screen will appear.
6. Press the
(Enter) key to edit the parameter.
7. Press the
or
key to change the value. If
desired, press the
key to move from digit to
digit, letter to letter, or bit to bit. The digit or bit that
you can change will be highlighted.
8. Press the
(Enter) key to save the value. If you
want to cancel a change, press the
key.
9. Press the
or
key to scroll through the
parameters in the group, or press the
key to
return to the group list.
Sel
Esc
Esc
F
GP: File
Monitor
Motor Control
Speed Command
FGP:
Par 55
Maximum Freq
60.00
Hz
25 <> 400.00
FGP:
Par 55
Maximum Freq
90.00
Hz
25 <> 400.00
F
G
P: Group
Motor Data
Torq Attributes
Volts per Hertz
FG
P
: Parameter
Maximum Voltage
Maximum Freq
Compensation