Param access – Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual
Page 45

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014
45
Programming and Parameters
Chapter 1
UT
IL
IT
Y
MOP Con
fig
194 [Save MOP Ref]
Enables/disables the feature that saves the present MOP frequency reference at power down or at
stop.
195 [MOP Rate]
Sets rate of change of the MOP reference in
response to a digital input.
Default:
Min/Max:
Units:
1.0 Hz/s
30.0 RPM/s
0.2/[Maximum Freq]
6.0/[Maximum Freq]
0.1 Hz/s
0.1 RPM/s
Dr
iv
e M
em
or
y
196 [Param Access Lvl]
Selects the parameter display level viewable on
the HIM.
• Basic = Reduced parameter set
• Advanced = Full parameter set
• Reserved = Full parameter set and
Engineering parameters (refer to the
PowerFlex Reference Manual).
This parameter is not reset when “Reset to
Defaults” is selected.
Default:
Options:
0
0
1
2
“Basic”
“Basic”
“Advanced”
“Reserved”
197 [Reset To Defalts]
Resets parameters to factory defaults except [Mtr
NP Pwr Units], [Speed Units], [Param Access Lvl],
[Language], [Voltage Class] & [TorqProve Cnfg]
(params 46, 79, 196, 201, 202 & 600).
• Option 1 resets parameters to factory defaults
based on [Voltage Class].
• Options 2 & 3 will set [Voltage Class] to low or
high and reset parameters to corresponding
factory defaults.
Important: Frames 5 & 6 - the internal fan
voltage may have to be changed when using
Option 2 or 3. See “Selecting /Verifying Fan
Voltage” in the Installation Instructions,
publication
.
Default:
Options:
0
0
1
2
3
“Ready”
“Ready”
“Factory”
“Low Voltage”
“High Voltage”
…
…
198 [Load Frm Usr Set]
Loads a previously saved set of parameter values
from a selected user set location in drive
nonvolatile memory to active drive memory.
Default:
Options:
0
0
1
2
3
“Ready”
“Ready”
“User Set 1”
“User Set 2”
“User Set 3”
199 [Save To User Set]
Saves the parameter values in active drive
memory to a user set in drive nonvolatile
memory.
Default:
Options:
0
0
1
2
3
“Ready”
“Ready”
“User Set 1”
“User Set 2”
“User Set 3”
200 [Reset Meters]
Resets selected meters to zero.
Default:
Options:
0
0
1
2
“Ready”
“Ready”
“MWh”
“Elapsed Time”
Fil
e
Gr
oup
No
.
Parameter Name & Description
See
page 16
for symbol descriptions
Values
Rela
ted
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 = Save
0 = Do Not Save
x = Reserved
Bit #
Factory Default Bit Values
At P
owr D
own
At
St
op