10
Utility mode
10-94
362/350/282/250/222/200
Utility mode
Chapter 10
Specifying settings to limit the use of communication modes-1 (mode
475)
Specify whether to permit or prohibit the use of individual communication
modes. Prohibited communication modes do not appear in their selection
screens.
2
Note
Programmed one-touch dial buttons can be used for transmission even
if a prohibited communication mode has been specified.
If all communication modes are prohibited (modes 475 to 477), some
screens, such as those for specifying transmission settings, may not nor-
mally be displayed.
Settings at time of purchase
Specifying the setting
During the production of this unit, the settings in the shaded cells were se-
lected. The numbers on the right side indicate the page numbers with de-
scriptions for the corresponding function.
Bit
7 6 5 4 3 2 1 0
Setting
0 0 0 0 0 0 0 0 (HEX: 00)
Bit
Description
Setting
Description
Page Refer-
ence
7
Specifies whether or
not the use of TCP/
IP is prohibited.
0
Permitted
----------
1
Prohibited
6
Specifies whether or
not the use of LPD is
prohibited.
0
Permitted
----------
1
Prohibited
5
Specifies whether or
not the use of a
RAW port is prohib-
ited.
0
Permitted
----------
1
Prohibited
4
Specifies whether or
not the use of SLP is
prohibited.
0
Permitted
----------
1
Prohibited
3
Specifies whether or
not the use of a
Scan to FTP is pro-
hibited.
0
Permitted
----------
1
Prohibited