beautypg.com

7 cleaning, 1 using the required supplies, Cleaning – HID HDPii Plus User Guide 2.0 User Manual

Page 81: Using the required supplies, 7cleaning

background image

HDP5000 & HDPii Card Printer Encoder User Guide_L000950, 2.0

December 2012

Page 81 of 103

© 2012 HID Global Corporation. All rights reserved.

Step

Procedure

5

If the tape test indicates inadequate adhesion, increase the heat setting by 5 degrees, print another card

and try the tape test again.

Once the temperature has been increased 4 times (20 degrees), reset temperature to default and

increase the Dwell Time by .5 second.

Repeat this process until adequate adhesion is achieved.

Ensure that the cards (in use) have a surface roughness (Ra) of 60 micro inches or less.

This information should be available from the card manufacturer.

7

Cleaning

For more information, reference the Cleaning Kit Instruction in the kit.
Important: Clean the Printer on a regular basis to ensure that the Printer consistently produces

high quality output.

WARNING: Disconnect the Printer's power cord whenever performing any

type of maintenance procedure unless otherwise directed.

7.1

Using the Required Supplies

For the maintenance procedures outlined for the Printer, you will need a Printer Cleaning Kit,

available from the reseller. This optional kit includes the following:

Printhead Cleaning Swabs pre-moistened with 99.99% isopropyl alcohol for cleaning the

Printer's Printhead.

Cleaning Cards with an adhesive backing for cleaning the Printer's Cleaning Rollers.

Gauze Pads pre-moistened with 99.99% isopropyl alcohol for cleaning the Printer's interior

and exterior.

Alcohol Cards pre-moistened with 99.99% isopropyl alcohol for cleaning the Printer's

Platen Rollers, Card Feed Rollers.

As with any electronic device, internal components of the Printer, such as

the Printhead may be damaged if exposed to static electrical discharges. To

avoid potential damage, always wear an appropriate personal grounding

device, such as a wrist strap (with integral resistor) connected to an ESD

ground. At a minimum, make positive contact with the bare metal chassis of

the Printer with the hand prior to touching any internal electrical

components.