beautypg.com

HID EDGE EVO EIM-M Input Module Installation Guide User Manual

Edge evo, Specifications, Wiring

background image

Specifications

CONDITIONS

VOLTAGE DC (VDC)

CURRENT (Amp) POWER (W)

OPERATING

TEmPERTURE

CAbLE LENGTh

UL REFERENCE

NUmbER

Inputs

DC Input (NSC)

+12VDC

0.03 Amp

0.36

32° - 122°F
(0° - 50° C)

Input Circuits
500 ft (150 m)

= 22 AWG ● 0.65mm ● 0.33mm

2

18 AWG ● 1.02mm ● 0.82mm

2

hi-O CAN bus Total Length 100 ft (30 m) -

22 AWG ● 0.65mm ● 0.33mm

2

Maximum between drops 30 ft (10 m)

22 AWG ● 0.65mm ● 0.33mm

2

MEIMAxNN

X = K for Black

G for Gray

+24VDC

0.03 Amp

0.72

DC Input (MAX)

+12VDC

0.04 Amp

0.48

+24VDC

0.04 Amp

0.96

Supervised Inputs (MAX)

0 to 5 VDC Reference

0.005 Amp (Sink)

0.025

NSC = Normal Standby Condition

Wiring

Input 1 Input 2

10

P3

1

Hi-O Group Select Jumper

Short = Group 1, Open = Group 2

Outside Door

Inside Door

( )

4

P1 1

* *

-

+

Input 3 Input 4

-

+

-

+

-

+

* Internal Optical Tamper Disable Jumper

CAN V+

GND

CAN H

CAN L

CANbus

Internal Optical Tamper

To disable the internal optical tamper sensor, attach a jumper wire from P3 pin 1 to P3 pin 2.

Note: If desiring an external tamper, wire an unsupervised Normally Closed contact, and replace the jumper.

EDGE EVO

®

Input Module

EIM-M

I

nstallatIon

G

uIde

82340-901, Rev C.2

March 2013

© 2009-2013 HID Global Corporation/ASSA ABLOY AB. All rights reserved.

15370 Barranca Parkway
Irvine, CA 92618-2215
USA

Optional

Supervised Inputs

1-6K

N/O

1-6K

N/C

1-6K

1-6K

N/O

Designed for interfacing to general purpose inputs typically not associated

with standard access point control, the Input Module provides an interface

to four input analog/digital inputs. The module is always configured as

general purpose input.