HID EDGE EVO EH400 Hi-O Controller Installation Guide User Manual
Edge evo, Hi-o networked controller, Specifications
EDGE EVO is the next evolution in access control hardware solutions. A true IP solution that meets the demands of open architecture,
IP-centric environments, EDGE EVO provides fully distributed intelligence and decision making right to the door, leveraging the IT
infrastructure to the maximum extent possible. Wire the EDGE EVO device to Hi-O interface modules providing connectivity to electronic
door components and access control readers.
Hi-O involves devices with built-in intelligence and a CANbus that links all the devices together. Password protect or encrypt Hi-O CANbus
data traffic. Each Hi-O device (such as the push plate, electric strike, card reader and door operator) is connected to the CANbus by a
single, four-wire cable. Two of the wires supply power and the other two are used for data communication.
Specifications
CONDITIONS
VOLTAGE DC (VDC)
CURRENT
(Amp)
OPERATING
TEMPERTURE
CABLE LENGTH
UL REF
NUMBER
Input
DC Input (NSC)
+12 VDC
0.14 Amp
32° - 122°F
(0° - 50° C)
Hi-O CAN Bus
Total Length 100 ft (30 m) -
22 AWG ● 0.65mm ● 0.33mm
2
Maximum between drops 30 ft (10 m)
22 AWG ● 0.65mm ● 0.33mm
2
RJ45
= 328 ft (100 m) - Category 5 K
E400CxNN
+24 VDC
0.08 Amp
PoE (+48VDC NOM)
0.05 Amp
DC Input (MAX)
+12 VDC
1.5 Amp
+24 VDC
1.5 Amp
PoE (+48 VDC NOM)
0.3 Amp
Ouput
CAN DC
Output
(MAX)
AUX 12 / 24 VDC Input
+10.8 to +24 VDC
1.2 Amp*
PoE Input
+ 24 VDC (NOM)
0.4 Amp*
NSC = Normal Standby Condition
* Combined output ratings are not to exceed 1.2 Amps (AUX Input) or 0.4 Amps (PoE Input).
X = K for Black
G for Gray
EDGE EVO
®
Hi-O Networked Controller
EH400
I
nstallatIon
G
uIde
82000-920, Rev C.0
October 2011
© 2009 - 2011 HID Global Corporation. All rights reserved.
15370 Barranca Parkway
Irvine, CA 92618-2215
USA