beautypg.com

HID EDGE EVO Solo ESH400-K Networked Controller Installation Guide User Manual

Edge evo, Specifications, Standard networked controller

background image

EDGE EVO is the next evolution in access control hardware solutions. A true IP solution that meets the demands of open architecture,

IP-centric environments, EDGE EVO provides fully distributed intelligence and decision making right to the door, leveraging the IT

infrastructure to the maximum extent possible. Leveraging Power-over-Ethernet (PoE), EDGE EVO reduces door installation costs by not

requiring a separate local power supply under many circumstances.
The Standard Networked Controller is a fully integrated single-door controller offering discrete I/O and Wiegand/Clock-and-Data interfaces

to readers. Additionally, connect native Hi-O devices (readers, locks, pushbuttons) and EDGE EVO Hi-O Modules to the Hi-O bus,

providing secure communication around the door. Hi-O involves devices with built-in intelligence and a CANbus that links all the devices

together. Password protect or encrypt Hi-O CANbus data traffic. Each Hi-O device (such as the REX switch, electric strike, card reader and

door operator) is connected to the CANbus by a single, four-wire cable. Two of the wires supply power and the other two are used for data

communication.

Specifications

CONDITIONS

VOLTAGE DC (VDC)

CURRENT

(Amp)

POWER (W)

OPERATING

TEMPERTURE CABLE LENGTH

UL REF

NUMBER

Input

DC Input (NSC)

+12VDC

0.18Amp

2.16

32° - 122°F

(0° - 50° C)

Hi-O CAN Bus Total Length 100 ft (30 m) -

22 AWG ● 0.65mm ● 0.33mm

2

Maximum between drops

30 ft (10 m)

22 AWG ● 0.65mm ● 0.33mm

2

RJ45

328 ft (100 m) - Category 5 K

KE400CX

1

X

2

N

+24VDC

0.14Amp

3.36

PoE
(+48VDC NOM)

.085Amp

4.08

DC Input (MAX)

+12VDC

1.5Amp

18.00

+24VDC

1.5Amp

36.00

PoE
(+48VDC NOM)

0.3Amp

14.40

Supervised inputs
(AC, Batt, REX, Door Mon) (MAX)

0-+5VDC Reference

0.005Amp
(sink)

0.025

Data 1/CLK , Data 0 / Data (MAX)

0-+5VDC Reference

N/A

N/A

Output

GRN LED, RED LED, Beep,
Hold (MAX)

0-+5VDC reference

0.005Amp
(sink)

0.025

External Tamper (MAX)

+5VDC (NOM)

0.02

0.100

CAN DC
Output
(MAX)

AUX 12 / 24VDC Input

+10.8 to +24VDC

1.2Amp *

28.80

PoE Input

+ 24VDC (NOM)

0.4Amp *

9.60

Reader
DC PWR
Output
(MAX)

AUX 12 VDC

+9.8 to +12.25VDC

0.32Amp *

3.92

AUX 24VDC

+9.8 to +12.25VDC

0.60Amp *

7.35

PoE Input

+9.8 to +12.25VDC

0.58Amp *

7.11

Strike***
/ AUX
Relays
NC or NO
DC Output
(MAX)

AUX 12VDC
Input

Unregulated (Wet)
Jumpers

+10 to +12VDC

0.70Amp *

8.40

AUX 24VDC
Input

Unregulated (Wet)
Jumpers

+23 to +24VDC

0.70Amp *

16.80

Regulated (Wet)
Jumpers - 12VDC

+10 to +12VDC

0.70Amp *

8.40

PoE Input

Unregulated (Wet)
Jumpers

+16.5 to +24VDC

0.36Amp *

8.64

Regulated (Wet)
Jumpers - 12VDC

+10 to +12VDC

0.58Amp *

6.96

AUX / PoE
Input

Jumpers Set
to Dry

+12 to +24VDC
External

2.00Amp **

48.00

NSC = Normal Standby Condition

* Combined output rating not to exceed V*I = W

1.2 Amp (+24VDC AUX Input, 28.8 W)

1.2 Amp (+12VDC AUX Input, 12.96 W)

EDGE EVO

®

Standard Networked Controller

EH400-K / ESH400-K

I

nstallatIon

G

uIde

82000-921, Rev D.1

October 2012

© 2009 - 2012 HID Global Corporation. All rights reserved.

15370 Barranca Parkway

Irvine, CA 92618-2215

USA

**

Each relay

*** Shared between relays.

X

1

=

K for Black

G for Gray

X

2

=

N for non-Solo

S for Solo