To download the Audit log file using these buttons, you need to log on with the Storage Adminis-
trator user account. The Audit Log Administrator Role needs to be set to Modify or View for the
operation authority setting for the user account.
NOTE:
Even though the FTP server settings are completed, the Audit:Warning button or the
Audit:Wraparound button might remain displayed on the Remote Web Console main panel. This
is due to the failure of transfer of the audit log information file. See “
” on page 101for how to resolve the problem.
•
The All Refresh button (
) allows you to update the information on the SVP and then display the
latest information on the Remote Web Console's main panel. When you click this button, all in-
formation displayed on XP Remote Web Console is reacquired from the array; therefore, it takes
time until the processing has completed.
CAUTION:
While an update is in process, other users are locked out of the XP Remote Web Console panels
and array maintenance and SVP operations. Because the update can take some time, you should
not use the All Refresh button unless you need to recover from an error.
NOTE:
If SVP maintenance is in progress, the XP Remote Web Console panel may not be properly
displayed even after you click All Refresh.
•
The exclusive lock icons indicate the operation mode of all currently logged-in users.
NOTE:
When a storage administrator is in Modify mode, storage partition administrators cannot change
to Modify mode. Only one storage partition administrator for each SLPR can be in Modify mode.
• If all users are operating in View mode, the blue Unlocked-shaped icon ( ) is displayed.
• If a user is operating in the Modify mode, the red Locked-shaped icon ( ) is displayed.
NOTE:
The display may show as Locked (
) when the SVP maintenance is in progress or if SNMP
operations are being performed.
•
The mode-switching button allows users to switch the operation mode between View (
) and
Modify (
). The button always shows the current user operation. Click the mode-switching button
to change modes.
Performing XP Remote Web Console Operations
74