beautypg.com

Localization quality of solutions – Spectra Precision Survey Pro v4.5 Recon and Nomad User Manual User Manual

Page 372

background image

User’s Manual – GPS Mode

362

status line will indicate the poor geometry of the control

points, or if the localization fails to solve, you will see a yellow

arrow and the status the status line will indicate the failure
to solve the localization.

Tapping Finish will apply the localization. If any of the horizontal or
vertical control toggles are changed in this screen before tapping

Finish, the button will change to Resolve, allowing you to re-compute

the quality before tapping Finish.

Tapping Occupy Additional Check Point opens the Occupy Control
screen, which allows you to collect another control point and add it to

the localization solution.

Localization Quality of Solutions

When solving a localization using the Basic GPS module, Survey Pro
will employ several mechanisms to ensure a quality solution.

Prompting For Extra Control Points: The Basic GPS

start survey work flow compels you to gather the minimum
number of points to solve the localization, and then it prompts

you to gather one more control point to be used as a check.
This step provides the redundancy required to verify the

quality of the solution.

Checking Control Point Relative Distance: Before

running the automatic blunder detection routine (described

below), the relative distance between control points is
checked. If control points are not spread far enough apart

relative to each other, then the blunder detection will not run

before solving the localization with the specified control
points, and a message will appear in the results area of the

localization screen. This is a good indication that the control

points will not be spaced evenly around the survey are and
maybe additional control points are required for this site.

Automatic Blunder Detection: When the control points are

spaced appropriately, Survey Pro will automatically attempt

to detect blunders with the localization solution. This is done

by looking at al the possible combinations of unique solutions
with the available control points and checking the extra