Watlow EZ-ZONE

®

RMH Module

71

Chapter 4 Setup Page

RM High Density Module

Setup Page

Display

Parameter Name

Description

Range

Default

Modbus

Relative

Address

CIP

Class

Instance

Attribute

hex (dec)

Profibus

Index

Parameter

ID

Data

Type

&

Read/

Write

[`Lnr]
[`Set]
Linearization Menu

[``Fn]
[ Fn]

Linearization (1 to 24)

Function

Set how this function will

linearize Source A.

[`oFF]

Off (62)

[intr]

Interpolated (1482)

[Stpd]

Stepped (1483)

Off

14388

[offset 70]

0x86 (134)

1 to 24

5

120

34005

uint
RWES

[SFn;A]
[SFn.A]

Linearization (1 to 24)

Source Function A

Set the type of function

that will be used for this

source.

[nonE]

None (61)

[``Ai]

Analog Input (142)

[CUrr]

Current (22)

[`C;Pr]

Cool Power, Control

Loop (161)

[`h;Pr]

Heat Power, Control

Loop (160)

[PWr]

Power, Control Loop

(73)

[`Lnr]

Linearization (238)

[MAt]

Math (240)

[``Pu]

Process Value (241)

[`SP;C]

Set Point Closed,

Control Loop (242)

[`SP;o]

Set Point Open, Con-

trol Loop (243)

[`uAr]

Variable (245)

None

14380

[offset 70]

0x86 (134)

1 to 24

1

- - - -

34001

uint
RWES

[`Si;A]
[ Si.A]

Linearization (1 to 24)

Source Instance A

Set the instance of the

function selected above.

1 or 250

1

14382

[offset 70]

0x86 (134)

1 to 24

2

- - - -

34002

uint
RWES

[`S2;A]
[ SZ.A]

Linearization (1 to 24)

Source Zone A

Set the zone of the function

selected above.

0 or 16

0

14384

[offset 70]

0x86 (134)

1 to 24

3

- - - -

34003

uint
RWES

[Unit]
[Unit]

Linearization (1 to 24)

Units

Set the units of Source A.

[`Src]

Source (1539)

[nonE]

None (61)

[`A;tP]

Absolute Temperature

(1540)

[`r;tp]

Relative Tempera-

ture (1541)

[PWr]

Power (73)

[`pro]

Process (75)

[``rh]

Relative Humidty

(1538)

Source

14436

[offset 70]

0x86 (134)

1 to 24

0x1D (29)

121

34029

uint
RWES

[`iP;1]
[ ip.1]

Linearization (1 to 24)

Input Point 1

Set the value that will be

mapped to output 1.

-1,999.000 to 9,999.000 °F or

units

-1,128.333 to 5537.223 °C

0.0

14394

[offset 70]

0x86 (134)

1 to 24

8

122

34008

float
RWES

[`oP;1]
[ op.1]

Linearization (1 to 24)

Output Point 1

Set the value that will be

mapped to input 1.

-1,999.000 to 9,999.000 °F or

units

-1,128.333 to 5537.223 °C

0.0

14414

[offset 70]

0x86 (134)

1 to 24

0x12 (18)

123

34018

float
RWES

Note:

Some values will be rounded off to fit in the four-character display.

Full values can be read with other interfaces.