beautypg.com

Alarm function – Watlow EZ-ZONE RMH User Manual

Page 125

background image

Watlow EZ-ZONE

®

RMH Module

122

Chapter 6 Features

Output

Output

Output Low

Pow

er Scale

Output

Tim

e Base

Output Control

Output

High P

ow

er Scale

Output Low

Pow

er Scale

Output

Tim

e Base

Output Control

Output

High P

ow

er Scale

Output Function
Output Function Instance

Output Source Zone
Output Source Error

Output Function
Output Function Instance
Output Source Zone
Output Source Error

Output Value

Output Value

Error

Error

Off

Digital

Alarm Function

This function's output changes state when Alarm Source

exceeds Alarm Set Point.
An error, when read, can indicate any of the following:
None, Open, Shorted, Measurement Error, Bad Cal Data,

Ambient Error, Fail, Not Sourced
Silenced : No, Yes
Alarm Latched : No, Yes
Alarm Clearable : No, Yes
Alarm Working Process Value : -1,999.000 to 9,999.000
Alarm Working Set Point : -1,999.000 to 9,999.000

Alarm

Instances - 24 per RMH

Alarm

Latc

hing

Alarm

Bloc

king

Alarm

Silencing

Alarm

H

ysteresis

Alarm

Clear Request

Alarm

Silence Request

Alarm

Type

Control Loop

Alarm

Logic

Alarm

Sides

Alarm

D

ispla

y

Alarm

D

ela

y Tim

e

Alarm

Low

Set P

oint

Alarm

H

igh Set P

oint

Output Value

Alarm Clearable

Alarm Working Process Value

Alarm Working Set Point

Alarm Latched

Alarm Silenced

Alarm State

Error

Alarm Source
Alarm Source Instance
Alarm Source Zone

Alarm Source Error

Control Loop

Overview

[Sr;A]

Alarm Source : Analog Input, Current, Power,

Linearization, Math, Process Value, Variable

[S2;A]

Alarm Source Zone : 0 to 16

[LooP]

Control Loop : 1 to 16

[iS;A]

Alarm Source

: 1 to 250

Instance

[A;ty]

Alarm Type : Off, Deviation, Process

[A;Lg]

Alarm Logic : Close on Alarm, Open on Alarm

[A;Si]

Alarm Silencing : Off, On

[A;LA]

Alarm Latching : Non-Latching, Latching

[A;dL]

Alarm Delay Time : 0 to 9,999 seconds

[A;CLr]

Alarm Clear Request : Ignore, Clear

[A;CLr]

Alarm Clear Request : Ignore, Clear

[A;Sir]

Alarm Silence Request : Ignore, Silence

[A;Sir]

Alarm Silence Request : Ignore, Silence

[A;hi]

Alarm High Set Point : -1,999.000 to 9,999.000

[A;hi]

Alarm High Set Point : -1,999.000 to 9,999.000

[A;hy]

Alarm Hysteresis : 0.001 to 9,999.000

[A;bL]

Alarm Blocking : Off, Startup, Set Point, Both

[A;Sd]

Alarm Sides : Both, High, Low

[A;dSP]

Alarm Display : Off, On

[A;Lo]

Alarm Low Set Point : -1,999.000 to 9,999.000

[A;Lo]

Alarm Low Set Point : -1,999.000 to 9,999.000

[ALM]
[SEt]

Alarm Menu

Setup Page

[ALM]
[

Alarm Menu
Operation Page

oPEr]

[A;St]

Alarm State : Startup,

Low, Alarm High, Error

None, Blocked, Alarm

[A;St]

Alarm State : Startup,

Low, Alarm High, Error

None, Blocked, Alarm

The alarm function causes outputs to change state when

Alarm Source exceeds alarm set points.

Alarm

Alarm

Latc

hing

Alarm

Bloc

king

Alarm

Silencing

Alarm

H

ysteresis

Alarm

Clear Request

Alarm

Silence Request

Alarm

Type

Control Loop

Alarm

Logic

Alarm

Sides

Alarm

D

ispla

y

Alarm

D

ela

y Tim

e

Alarm

Low

Set P

oint

Alarm

H

igh Set P

oint

Output Value

Alarm Clearable

Alarm Working Process Value

Alarm Working Set Point

Alarm Latched

Alarm Silenced

Alarm State

Error

Alarm Source

Alarm Source Instance
Alarm Source Zone
Alarm Source Error

Control Loop

Off

If Alarm Type = Off, Output Value = Off
If Alarm State = None, Alarm Indication = None