3. SCON-CA/CF

A


82


(2) I/O signal assignments for each axis

An I/O signal of each axis consists of 16 bytes of I/O addresses.

z Control signals and status signals are bit ON/OFF signals.

z The target position and current position are both 4 bytes (32-bit) binary data. Although values from -999999 to

+999999 (unit: 0.01 mm) can be handled by the PLC, set position data within the software stroke range (0 up
to the effective stroke length) of the applicable actuator.

z Set a desired positioning band. The positioning band is 4 bytes (32-bit) binary data and values from 1 to

+999999 (unit: 0.01 mm) can be handled by the PLC.

z The specified speed is 2 bytes (16-bit) binary data. Although values from 0 to +65535 (unit: 1.0 mm/sec or 0.1

mm/sec) can be handled by the PLC, set a value not exceeding the maximum speed of the applicable
actuator.

z The setting of unit can be established in Parameter No. 159 FB Half Direct Mode Speed Unit.

Parameter No.159 Setting Value

Indicated Speed Unit

0 1.0mm/sec
1 0.1mm/sec

z The acceleration/deceleration is 2 bytes (16-bit) binary data. Although values from 1 to 300 (unit: 0.01 G) can

be handled by the PLC, set a value not exceeding the maximum acceleration and maximum deceleration of
the applicable actuator.

z The push-current limiting value is 2 bytes (16-bit) binary data. Although values from 0 (0%) to 255 (100%) can

be handled by the PLC, set a value within the specifiable range of push-current limiting values of the
applicable actuator (refer to the catalog or operation manual for the actuator).







z The command current is 4 bytes (32-bit) binary data (unit: 1 mA).

z The current position is 4 bytes (32-bit) binary data (unit: 0.01 mm/sec).

z The alarm code is 2 bytes (16-bit) binary data.

Set value

Push-current
limiting value

127