5. Flow and Commands of Basic MECHA

TROLINK Communication



211



[4] CONNECT command

Command Code

Name

CONNECT 0E

H

Command to connect to the MECHATROLINK network

When this command is completed, the phase moves into phase 2 or 3 in which communication is allowed.
Use this command to set the communication mode (synchronous or asynchronous communication).
The connection is established between the master unit and the specified slave.
You can check if the process is completed by checking CMDRDY=1 in the STATUS field.

z MECHATROLINK-II field content

Field (Signal) name

Value

Description

VER

21H

MECHATROLINK-II = 21H

BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0

DATA_EXP

0 0 0 DTMOD

SYNCMOD

0

1 32-byte

mode

DATA_EXP

0 17-byte

mode

1

Set-up not allowed

DTMOD

0 Single

phase

communication

1

Set-up not allowed

COM_MODE

SYNCMOD

0 Asynchronous

communication

COM_TIME

Set-up not required

z MECHATROLINK-I field content

Field (Signal) name

Value

Description

VER

10H

MECHATROLINK-I = 10H

BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0

0 0 0 0 DTMOD

SYNCMOD

EXMOD

1

Set-up not allowed

DTMOD

0 Single

phase

communication

1

Set-up not allowed

SYNCMOD

0 Asynchronous

communication

1

Expandable connection (SYNCMOD is disregarded)

COM_MODE

EXMOD

0

Standard connection -- This is to be selected usually.

COM_TIME

Set-up not required