Precautions for use, 1 setting the acceleration/deceleration – IAI America IX-NSN6016H User Manual
Page 95
![background image](/manuals/350281/95/background.png)
87
1
1. Precautions for Use
11. Precautions for Use
11.1 Setting the Acceleration/Deceleration
Set the acceleration/deceleration using the graphs below as a reference.
(1) PTP operation (Set using the SEL language commands ACCS and DCLS.)
IX-NNN50
H/60 H/70 H/80 H, IX-NNW50 H/60 H/70 H/80 H,
IX-NNC50
H/60 H/70 H/80 H
Acceler
ation deceleration (%)
Acceler
ation deceleration (%)
IX arm length 500/600
Reference settings for PTP
acceleration/deceleration
IX arm length 500/600
Reference duties for PTP
continuous operation
Maximum
setting range
Reference range for
continuous operation
Reference range of duty for
continuous operation duty
Duty (%)
Inertial moment (kg-m)
Duty (%) = (Continuous operation /
(Continuous operation + Stopping time)) / 100
Mass of carrying load (kg)
Axis 4 (rotation
axis) only
Acceler
ation deceleration (%)
Acceler
ation deceleration (%)
IX arm length 700/800
Reference settings for PTP
acceleration/deceleration
IX arm length 700/800
Reference duties for PTP
continuous operation
Maximum
setting range
Reference range for
continuous operation
Reference range of duty for
continuous operation duty
Duty (%)
Inertial moment (kg-m)
Duty (%) = (Continuous operation /
(Continuous operation + Stopping time)) / 100
Mass of carrying load (kg)