Caution – IAI America IX-NSN6016H User Manual
Page 113
105
1
1. Precautions for Use
x Be sure to use clean, dry air with an atmospheric dew point of -20qC or less. If dry air is not used,
condensation may occur inside the robot, resulting in earth leakage or malfunction.
x Do not apply pressure exceeding the specified maximum pressure of 0.6 MPa. Doing so may cause the
seals to break and impair the robot’s dust-proof/drip-proof performance.
x Adjust the pressure and also adjust the flow rate using the speed controller at the back of the base to
prevent intrusion of powder dust.
Caution
This manual is related to the following products: