Caution – IAI America IX-NSN6016H User Manual
Page 114
![background image](/manuals/350281/114/background.png)
106
1
1. Precautions for Use
11.6.2 IX-NNW70
H/80H
An IP65 dust-proof/splash-proof specification can be achieved by applying the pressure specified below from the
air supply port provided on the side face of the base.
x The air supply source (relief valve, etc.) and air tubes (6) are provided by the customer.
x The speed controller is already adjusted to the specified pressure, so you need not adjust the needle.
Service pressure 0.2 to 0.3 (MPa)
Pipe size
Outer diameter
6 x Inner diameter 4
Fluid used
Clean, dry air free from compressor oil, etc. The air filtration rating shall be 10
Pm or less,
dew point of dry air in atmosphere shall be -20
qC or less.
z Adjustment of supply pressure
Do not add all supply pressure in one go.
Gradually increase the supply pressure to a level of 0.2 to 0.3 MPa.
x Be sure to use clean, dry air with an atmospheric dew point of -20qC or less. If dry air is not used,
condensation may occur inside the robot, resulting in earth leakage or malfunction.
x Do not apply pressure exceeding the specified maximum pressure of 0.3MPa. Doing so may cause the
seals to break and impair the robot’s dust-proof/drip-proof performance.
x The speed controller is already adjusted to the specified pressure, so do not adjust the needle. If the needle
is adjusted, dust-proof/splash-proof performance may drop.
Air supply port for air purge
(speed controller)
Applicable tube:
Outer diameter
6
(inner diameter
4)
To air supply
source
Caution