Determine which unit will be set up as the Master. The other unit will be set up as the Slave. It doesn’t matter
which unit is which, but you must identify the Master and Slave operators by taking the following steps:
S.T.A.R.T. by configuring the MASTER unit.

1. At a gate status display, press the MENU button

twice. This accesses the User Menu and the
CLOSE TIMER display appears.

2. Simultaneously, press the OPEN and RESET

buttons to enter the Installer Menu. Release the
buttons and the USAGE CLASS display appears
which is the first item in the Installer Menu.

3. Press NEXT until the DUAL GATE display

appears. The factory default setting is 0.

4. Use the SELECT and NEXT buttons to

navigate and change the setting to 2 MASTER.

5. To exit the Installer Menu, press the MENU

button. A gate status appears in the display
indicating you have returned to Run Mode.
Note:For proper operation, you must set the other
gate operator as SLAVE.

6. Move to the other SwingSmart operator.
7. Using the buttons on the Smart DC Controller,

access the DUAL GATE display through the
Installer Menu.

8. Perform the same steps, 1 through 5, but address

the operator as SLAVE, setting 1.

When the SwingSmart operator has been designated
as the master and the other as slave, the dual-gate
operators will be in constant communication, most
often, in a peer-to-peer relationship. For example,

Any control input that is attached to the slave unit
will be recognized by the master once the Installer
Menu is properly configured in both units.

A diagnostics log is maintained in each unit, but
both units run and store the errors codes and
diagnostics pertinent to each other.

The master unit controls the close timer even if the
timer is set in the slave unit. If a close timer is set in
both units, the master unit overrides the slave setting.

NOTE

If the dual-gate communication stops for whatever reason, (communication wire severed or the
power switch is turned off in one unit), both operators cease to function and an ERR4 (Master/
Slave Communication Error) appears in the display.

HYSECURITY

GATE CLOSED

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

CT 0 (OFF)

CLOSE TIMER

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

UC 2

USAGE CLASS

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

DG 2 (MASTER)

DUAL GATE

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

1. S.T.A.R.T. at a gate
status display.

2. Access the User
Menu by pressing
MENU twice.

3. Access the Installer
Menu, by
simultaneously
pressing OPEN and
RESET. Release the
buttons.

4. Use NEXT to
navigate to the menu
display. Change the
setting using the
SELECT and NEXT
buttons.

This manual is related to the following products: