Nstalling, Olenoid, Installing a lock for 12vdc or 24vdc systems -3 – Controlled Products Systems Group SWINGSMART DC 20 User Manual
Page 101: Installing a lock for 12vdc or 24vdc systems
![background image](/manuals/335044/101/background.png)
Installing a MagLock or Solenoid Lock
Revision E
Reference
6-3
I
NSTALLING
A
M
AG
L
OCK
OR
S
OLENOID
L
OCK
To provide additional gate security, a maglock or a solenoid lock can be used and connected to the Smart DC
Controller. The Smart DC Controller releases the gate prior to initiating gate movement. Before installing the
lock, be sure to:
•
Determine the electrical power requirements of your lock (maglock or solenoid lock). Electronic board and
peripheral connections differ between high voltage and lower voltage gate operators.
•
Determine the current required. The 24VDC, 24VAC, or 12VDC terminals supply up to 1 ampere. If the
peripherals attached to the terminals need more than 1 amp, a separate power supply is required.
Installing a Lock for 12VDC or 24VDC Systems
To install a lock for 12VDC or 24VDC
systems, take the following steps:
1. Connect a wire between COM on
USER 1 RELAY and a COM terminal
on the electronics board. See Figure 6-2.
2. Connect the power lead from the lock
to the appropriate power spade
(+24VDC or +12VDC)
3. Connect the common wire from the
lock to NC on USER 1 RELAY.
Note:Connect to NO on USER 1
RELAY if installing a Solenoid lock.
4. Set the User Relay function in the
Installer Menu to RL1 - 6. Refer to
Setting the User Relay Function in the
Installer Menu
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
RADIO
CLOSE
OPEN
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
U
SE
R2
COM NO
DC
USER 1 RELAY
NO NC
COM
24VDC
24VDC
24VAC
24VAC
12VDC
12VDC
AƩach the power wire from the lock
to the appropriate power spade.
Connect COM on board
to COM on USER 1 RELAY.
Connect the COM wire from
the lock.
A Solenoid lock aƩaches to NO.
A MagLock aƩaches to NC.
Figure 6-2.
1
2
3