Initial Setup

Revision E

Display and Menu Options

3-3

Using the Smart DC Controller Buttons In Menu Mode

The buttons on the Smart DC Controller let you navigate, change, or clear the information in the display
menus. Refer to Figure 3-2.

The buttons with text above and below are variable function keys (VFK). Use these buttons to enter or change
operational data and navigate through the User and Installer Menus. The singular use of a variable function key
is dependent on operator mode. Three different modes exist:

Run Mode - gate is operational awaiting commands. Refer to

Using the Smart DC Controller Buttons In

RUN Mode

.

Menu Mode - motor disengages and operator commands are ignored. Data entry, menu navigation, and
menu selection can be accomplished via the Controller buttons or through a S.T.A.R.T. software
connection using the USB port.

Fault Mode - errors, faults or alerts appear on the display. Some errors or faults can be reset with the STOP
button while more serious faults require the RESET button or cycling power, and then pressing RESET.
Faults indicate a need for diagnosis and resolution. Refer to

Smart DC Controller Troubleshooting

.

Figure 3-2. Function of the Smart DC Controller Buttons in Menu Mode

Pressing SELECT
causes the upper two characters to blink,
which indicates the display is ready to
accept changes to a menu setting.

Press SELECT a second time to accept
what appears on the display. The entry
mode is complete when the two characters
stop blinking.

CT 0 (OFF)

CLOSE TIMER

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

Pressing PREV
moves to the previous
menu selection.

Pressing NEXT
advances through the next available
menu selection.

Pressing RESET
resets faults and
returns to Run
Mode. A gate
status display
appears.

Note: The
RESET button
cannot be used to
exit Menu Mode.

Pressing MENU
returns to Run Mode and a gate
status display appears.

Note: The MENU button does
not function while the selection
is still blinking.

Two blinking characters
indicate that the display
will accept changes.