Racket, Inkage, Installing the gate bracket -7 – Controlled Products Systems Group SWINGSMART DC 20 User Manual
Page 29: Installing the gate bracket
Gate Bracket and Linkage Arms
Revision E
Installation
1-7
G
ATE
B
RACKET
AND
L
INKAGE
A
RMS
Installing the Gate Bracket
Figure 1-7.
1. Secure the gate to prevent movement.
CAUTION
!
If vertical bars make up the gate design, be sure to install a horizontal cross member to provide
the necessary support to the gate arm. Do not mount the bracket to a small number of vertical
pickets. Pickets will bend in the event of a gate strike.
2. Determine the proper position of the gate bracket. Use the chart for reference.
Hint: Determine if you have a short, medium, or long gate. If the X and Y dimensions in the chart are the
same as your install, set the gate bracket at the Xg dimension. If your install does not fit to the chart specs,
use the Custom Gate Installation formula to determine the proper gate bracket placement.
3. Measure and position the gate bracket so it is level with the arm on the operator. Clamp the gate bracket to
the horizontal cross member.
Short Gate Installation:
For gates up to 10 feet (3 meters)
X
Y
Xg
14"
23.5"
10.5"
18"
27.5"
Medium Gate Installation:
For gates up to 13 feet (4 meters)
Long Gate Installation:
For gates up to 20 feet (6 meters)
Custom Gate Installation:
X
Y
Xg
X + Y - 1
36cm
27cm
60cm
46cm
70cm
20"
29.5"
51cm
75cm
X
Y
Xg
22"
33"
12"
24"
35"
56cm
31cm
84cm
61cm
89cm
28"
39"
71cm
99cm
X
Y
Xg
30"
44"
15"
35"
49"
76cm
38cm
112cm
89cm
124cm
40"
54"
101cm
137cm
Operator Center
Photo eye
Horizontal
cross member
Hinge Center
X
Y
Xg