Operation notes: -11 – Controlled Products Systems Group SWINGSMART DC 20 User Manual
Page 109

Installing Photoelectric Sensors For Secondary Entrapment Protection Only
Revision E
Reference
6-11
O
PERATION
N
OTES
:
•
A photo eye trip does not reverse gate.
•
The Smart DC Controller software is factory set to stop upon photo eye trip.
•
Software is configurable to stop and reverse two seconds upon photo eye trip.
•
If the photo eye is cleared within five seconds, the gate will proceed in the direction of travel.
There are two common types of photoelectric
sensors, thru-beam and retro-reflective, and each
has its advantages.
•
A thru-beam sensor is generally more
powerful and able to function reliably with
dirty optics and in poor weather.
•
A retro-reflective sensor does not require the
installation and extra wiring of a separate
emitter and receiver as is required in a thru-
beam system, but retro-reflective eyes are
generally more problematic in poor weather.
Avoid using retro-reflective devices across
outdoor distances greater than 24 feet (7.3m)
because of performance and reliability issues.
Mount thru-beam type photo eyes approximately
15" to 30" (38cm to 76cm) above the ground
and as close to the gate as possible. A minimum
of two photo eyes are required, one photo eye to
guard the open direction and the other for the
close direction of travel, unless gate edges for
entrapment protection are installed. Mount the
emitters and the receivers just beyond the travel
of the gate in both the full open and full closed
positions of travel. The installation locations
described above are intended for pedestrian
detection. If photo eyes are to be used for
vehicular detection, install a low elevation photo
eye for cars and another photo eye at a height of
about 55" (140cm) to detect semi-trucks.
NOTE
If photo eyes are to be used for vehicle detection and logically function the same as a vehicle
detector, connect the common wires to the COM terminals on the left side of the board and
wire the NO output contact to the appropriate vehicle detector input: EXIT LOOP, IN OBS
LOOP, and OUT OBS LOOP.
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
RADIO
EDGE +24V O
Figure 6-10. Connections for Entrapment
Protection only
Photo Eye Open
Direction
Photo Eye Close
Direction
Photo Eye COM
terminal
Photo Eye +24 VDC
Note:
EYE COM & +24V is the recommended way to
connect standard photo eyes to Smart DC Controller.
Other options include:
•
Photo eye ON continuously: COM & +24VDC
or +24VAC (if the photo eye uses 24VAC).
•
Photo eye ON continuously with anti-fog feature:
COM & +24VAC (connecting to DC will
negatively affect battery charging).
•
Photo eye and peripherals draw more than 1A off
one power supply: Requires a separate power
supply connected to the service outlet.