Iring, Ac p, Ower – Controlled Products Systems Group SWINGSMART DC 20 User Manual
Page 41
Wiring AC Power
Revision E
Power
2-3
W
IRING
AC P
OWER
DANGER
!
Turn off AC power at the source (circuit breaker panel) before accessing the wires in the Swing-
Smart junction box. Follow facility Lock Out/Tag Out procedures. Make sure both the DC and AC
power switches, on the side of the SwingSmart control box are in the off position. See Figure 2-2.
CAUTION
!
Wiring of gate operators must conform to the NEC standards and comply with all local codes.
If you plan to connect to 208/230VAC power, read the WARNING in Figure 2-2. The voltage
selector switch on the AC Power board must be moved to the 230V position or damage to the
operator will occur and void the Limited Warranty.
Figure 2-2.
WARNING
Place the power switches in the
OFF position.
Service outlet
115 VAC wires for the service outlet.
Junction box cover and label
Voltage selector switch is
factory set to 115V.
If power input is 208/230V,
move the switch so 230V
appears and change the
label on the junction
box cover.
The service outlet is wired for 115VAC. To
use the 115VAC service outlet on a 208/
230VAC installation, the electrician needs
to run an extra neutral wire to the operator
from the power source and wire the service
outlet per code.
High voltage
protection cover.
NOTE: For 208VAC a separate transformer option
kit may need to be ordered.