Installing a lock on 24vac systems, Installing a lock for high voltage systems, Figure 6-3 – Controlled Products Systems Group SWINGSMART DC 20 User Manual
Page 102: Figure 6-4
Installing a MagLock or Solenoid Lock
6-4
SwingSmart DC Installation and Reference Manual
Revision E
Installing a Lock on 24VAC Systems
To install a lock for 24VAC systems, take
the following steps:
1. Connect a wire from COM on USER
1 RELAY and one 24VAC power
spade. See Figure 6-3
2. Connect a power lead from the lock to
the remaining 24 VAC power spade.
3. Connect the remaining power lead
from the lock to the NC terminal on
USER 1 RELAY.
Note:Connect to NO on USER 1
RELAY if installing a Solenoid lock.
4. Set the User Relay function in the
Installer Menu to RL1 - 6. Refer to
Setting the User Relay Function in the
Installer Menu
.
Installing a Lock for
High Voltage
Systems
To install a lock on higher voltage systems (115V or
230V), take the following steps:
1. Connect one lead of the power supply to one lead
of the lock’s coil. See Figure 6-4.
2. Connect the other lead of the lock’s coil to NO on
USER 1 RELAY.
Note:Connect to NC on USER 1 RELAY if installing
a maglock.
3. Connect the COM on USER 1 RELAY to the
second lead wire in the power supply (115V or
230V).
4. Set the User Relay function in the Installer Menu
to RL1 - 6. Refer to
Setting the User Relay Function in the Installer Menu
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
RADIO
CLOSE
OPEN
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
U
SE
R2
COM NO
DC
USER 1 RELAY
NO NC
COM
24VDC
24VDC
24VAC
24VAC
12VDC
12VDC
AƩach the power lead from the lock
to the 24VAC power spade.
Connect to COM on
USER 1 RELAY.
Connect the power lead from the lock’s coil to:
NC for a MagLock
NO for a Solenoid lock
Figure 6-3.
1
2
3
High voltage
High voltage
115VAC
230VAC
Lock
USER 1 RELAY
NO
COM
POWER SUPPLY
Figure 6-4.
1
2
3