beautypg.com

Gcm 8000 limitations – CTI Products MCN Server 8000 User Manual

Page 42

background image

Interfacing to IP Comparators

GCM 8000 Comparators

42

68-12286-110

GCM 8000 Subsite Assignment (BR/CM Pairing) Programmed in BR

The Subsites (BRs or receivers) are not assigned in the CSS for the GCM 8000 comparator. The Subsite
numbers are assigned in the CSS for each of the GTR 8000 BRs and the GPW 8000 Satellite Receivers
as shown below:

GCM 8000 Limitations

The GCM 8000 comparator has the following limitations

Maximum of 3 Simultaneous MCN Servers or CSS Sessions

The GCM 8000 supports only 3 simultaneous connections for real-time sessions. These sessions
include:

CTI MCN Server 8000 Software

CSS Software

From a practical standpoint, this means that you should limit the number of MCN Servers talking to a
GCM 8000 comparator to two. This will allow an open session for the CSS software.

MCN Server & CSS cannot run simultaneously on the same PC

The GCM 8000 comparator cannot talk to both the MCN Server software and the CSS software running
on the same PC simultaneously.

If you have to run CSS on the Server PC, you will have to exit the MCN Server software.

If you have the CSS software running on the Server PC and try to start the MCN Server
software, it will not communicate to the GCM 8000 comparator.