CTI Products MCN Server 8000 User Manual
Page 190
![background image](/manuals/334837/190/background.png)
Advanced Configuration
Configuring Master-Sub Comparator with Multi-Dependency
190
68-12286-110
To build this display we us the Display Table Override feature. For each receiver in a Display Window
that will use a different Display Table than chosen in the Receivers Window, right-click its cell in the
Display Window as shown below.
Then click the Override Display Table menu item to display the following window.
Choose Sub A, and then click OK. The Display Window will indicate receivers with Display Table
Overrides with a Reddish background as shown below. The cells for other receivers using their default
Display Table will have a green background.
Repeat this procedure for each receiver that should have an override for the default Display Table.
The Display Table for all receivers of a comparator can be overridden. And taking it a step further, the
Display Table for all receivers in a Display Window can be overridden. To apply Display Table
Overrides to many receivers at once, perform the following steps:
• Select all receivers that you wish to override with a type of Display Table.
• Right-click the selection, then click the Override Display Table menu item to display the
Override Display Table window.
• Select the proper Display Table from the list, then click OK.
Right –click to choose Override Display Table