beautypg.com

Data formats and i/o ranges – Advantech Data Acquisition Modules ADAM 4000 User Manual

Page 384

background image

Data Formats and I/O Ranges

B-8 ADAM 4000 Series User’s Manual



Range
Code
(hex)

Input Range
Description

Data Formats

Maximum
Specified
Signal

Minimum
Specified
Signal

Displayed
Resolution

0F

Type K
Thermocouple
0°C to 1370°C

Engineering
Units

+1370.0 +0000.0 0.1°C

% of FSR

+100.00

+000.00

0.01%

Twos
Complement

7FFF 0000 1

LSB*

10

Type T
Thermocouple
-100°C to 400°C

Engineering
Units

+400.00 -100.00 0.01°C

% of FSR

+100.00

-0.25.00

0.01%

Twos
Complement

7FFF E000 1

LSB*

11

Type E
Thermocouple
0°C to 1000°C

Engineering
Units

+1000.0 +0000.0 0.1°C

% of FSR

+100.00

+000.00

0.01%

Twos
Complement

7FFF 0000 1

LSB*

12

Type R
Thermocouple
500°C to 1750°C

Engineering
Units

+1750.0 +0500.0 0.1°C

% of FSR

+100.00

+028.57

0.01%

Twos
Complement

7FFF 2492 1

LSB*

13

Type S
Thermocouple
500°C to 1750°C

Engineering
Units

+1750.0 +0500.0 0.1°C

% of FSR

+100.00

+028.57

0.01%

Twos
Complement

7FFF 2492 1

LSB*

14

Type B
Thermocouple
500°C to 1800°C

Engineering
Units

+1800.0 +0500.0 0.1°C

% of FSR

+100.00

+027.77

0.01%

Twos
Complement

7FFF 2381 1

LSB*

20

100.00 Ω
Platinum RTD
α = .00385
-100°C to 100°C

Engineering
Units

+100.00 -100.000 0.1°C

% of FSR

+100.00

+000.00

0.01%

Twos
Complement

7FFF 8000 1

LSB*

Ohms +138.50

+060.60

10

mΩ

21

100.00 Ω
Platinum RTD
α = .00385
0°C to 100°C

Engineering
Units

+100.000 +000.00 0.1°C

% of FSR

+100.00

+000.00

0.01%

Twos
Complement

7FFF 0000 1

LSB*

Ohms +138.50

+100.00

10

mΩ