4018M
@AAT
Name
Read Memory Operation Mode command
Description
Request the memory operation status of the analog input
data logger at address AA.
Syntax
@AAT (cr)
@
is a delimiter character.
AA
(range 00-FF) represents the 2-character hexadecimal
address of an analog input data logger.
T
is the Read Memory Operation Mode command.
(cr)
is the terminating character, carriage return (0Dh).
Response
!AAO(cr)
if the command is valid.
!
is a delimiter character indicating a valid command was
received.
AA
(range 00-FF) represents the 2-character hexadecimal
address of an analog input module.
O
represents the operation mode:
‘1’: enables the recording of data.
‘0’: disables the recording of data.
(cr)
is the terminating character, carriage return (0Dh).
Example
command: @F3T(cr)
response: !F31(cr)
The command requests the memory operation status of the
analog input data logger at address F3.