beautypg.com

Rainbow Electronics DS26503 User Manual

Page 50

background image

DS26503 T1/E1/J1 BITS Element

50 of 123


Register Name:

SR2

Register Description:

Status Register 2

Register Address:

16h


Bit

# 7 6 5 4 3 2 1 0

Name RYELC

RAISC

RLOSC

RLOFC

RYEL RAIS RLOS RLOF

Default

0 0 0 0 0 0 0 0

HW
Mode

X X X X X

RAIS

PIN 29

RLOS

PIN 32

LOF

PIN 30


Bit 0/Receive Loss of Frame Condition (RLOF). Set when the DS26503 is not synchronized to the received data stream.

Bit 1/Receive Loss Of Signal Condition (RLOS). Set when 255 (or 2048 if E1RCR.6 = 1) E1 mode or 192 T1 mode
consecutive zeros have been detected. In 6312kHz Synchronization Interface Mode, this bit will be set when the signal
received is out of range as defined by the G.703 Appendix II specification.

Bit 2/Receive Alarm Indication Signal (T1= Blue Alarm, E1= AIS) Condition (RAIS). Set when an unframed all-ones
code is received.

Bit 3/Receive Yellow Alarm Condition (RYEL). (T1 only) Set when a yellow alarm is received.

Bit 4/Receive Loss of Frame Clear Event (RLOFC).
Set when the framer achieves synchronization; will remain set until
read.

Bit 5/Receive Loss Of Signal Clear Event (RLOSC).
Set when loss of signal condition is no longer detected.

Bit 6/Receive Alarm Indication Signal Clear Event (RAISC). Set when the unframed all-ones condition is no longer
detected.

Bit 7/Receive Yellow Alarm Clear Event (RYELC).
(T1 only) Set when the yellow alarm condition is no longer detected

.