Rainbow Electronics GM862-QUAD-PY User Manual
Page 337

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 337 of 434
#SKTTO - Socket Inactivity Time-Out
SELINT 0 / 1
AT#SKTTO[=
[
Set command sets the maximum time with no data exchanging on the
socket that the module awaits before closing the socket and deactivating
the GPRS context.
Parameter:
0 - no time-out.
1..65535 - time-out in sec. units (factory default is 90).
Note: this time-out applies when no data is exchanged through the socket
for a long time and therefore the socket connection has to be automatically
closed; the GPRS context is deactivated only if it has been activated issuing
#SKTOP; if it has been activated issuing #SKTD, now it stays activated.
Note: issuing AT#SKTTO
Note: issuing AT+#SKTTO=
AT+#SKTTO=0
AT#SKTTO?
Read command reports the current socket inactivity time-out value.
AT#SKTTO=?
Test command returns the allowed values for parameter
Example
AT#SKTTO=30 ->(30 sec. time-out)
OK
AT#SKTTO?
#SKTTO: 30
OK
#SKTTO - Socket Inactivity Time-Out
SELINT 2
AT#SKTTO=
[
Set command sets the maximum time with no data exchanging on the
socket that the module awaits before closing the socket and deactivating
the GPRS context.
Parameter:
0 - no time-out.
1..65535 - time-out in sec. units (factory default is 90).
Note: this time-out applies when no data is exchanged in the socket for a
long time and therefore the socket connection has to be automatically
closed; the GPRS context is deactivated only if it has been activated issuing
#SKTOP; if it has been activated issuing #SKTD, now it stays activated.
Note: this command is not allowed for sockets associated to a GSM context
(see #SCFG).
AT#SKTTO?
Read command reports the current socket inactivity time-out value.
AT#SKTTO=?
Test command returns the allowed values for parameter
Example
AT#SKTTO=30 ->(30 sec. time-out)