AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 182 of 434

+CSCB -Select Cell Broadcast Message Types

SELINT 0 / 1

[
[,
[,]]]]

received by the device.

Parameter:

0 - the message types defined by and are accepted

(factory default)

1 - the message types defined by and are rejected
- Message Identifiers, string type: all different possible

combinations of the CBM message identifiers; default is empty
string (“”).

- Data Coding Schemes, string type: all different possible

combinations of CBM data coding schemes; default is empty string
(“”).


Note: the current settings are stored through +CSAS

Note: issuing AT+CSCB is the same as issuing the Read command.

Note: issuing AT+CSCB= is the same as issuing the command
AT+CSCB=0.

AT+CSCB?

Read command reports the current value of parameters ,
and .

AT+CSCB=?

Test command returns the range of values for parameter .

Example

AT+CSCB?

+CSCB: 1,"",""

OK

(all CBMs are accepted, none is rejected)

AT+CSCB=0,"0,1,300-315,450","0-3"
OK

Reference

GSM 07.05, GSM 03.41, GSM 03.38.


CSCB -Select Cell Broadcast Message Types

SELINT 2

AT+CSCB=
[[,
[,]]]

Set command selects which types of Cell Broadcast Messages are to be
received by the device.

Parameters:

0 - the message types defined by and are accepted

(factory default)

1 - the message types defined by and are rejected
- Message Identifiers, string type: all different possible

combinations of the CBM message identifiers; default is empty
string (“”).

- Data Coding Schemes, string type: all different possible

combinations of CBM data coding schemes; default is empty string
(“”).