Rainbow Electronics GM862-QUAD-PY User Manual
Page 267

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 267 of 434
#VAUX- Auxiliary Voltage Output Control
SELINT 0 / 1
Note: when
#VAUX:
where:
0 - output off
1 - output on
Note: If all parameters are omitted the command has the same behaviour
as Read command.
Note: for the GPS product (GE863-GPS): if the Auxiliary Voltage pin output
is disabled while GPS is powered on they’ll both also be turned off.
AT#VAUX?
Read command reports whether the Auxiliary Voltage pin output is currently
enabled or not, in the format:
#VAUX:
AT#VAUX=?
Test command reports the supported range of values for parameters
#VAUX- Auxiliary Voltage Output Control
SELINT 2
AT#VAUX=
[
Set command enables/disables the Auxiliary Voltage pins output.
Parameters:
1 - there is currently just one VAUX pin
1 - output on
2 - query current value of VAUX pin
Note: when
#VAUX:
where:
0 - output off
1 - output on
Note: for the GPS product (GE863-GPS): if the Auxiliary Voltage pins output
is disabled while GPS is powered on they’ll both also be turned off.
Note: the current setting is stored through #VAUXSAV
AT#VAUX?
Read command reports whether the Auxiliary Voltage pin output is currently