+CRSL - Ringer Sound Level

SELINT 0

1 - low
2 - middle
3 - high
4 - progressive

Note: if parameter is omitted then the behaviour of Set command is the
same as Read command

AT+CRSL?

Read command reports the current setting of the call ringer in the
format:

+CRSL:

AT+CRSL=?

Test command reports supported values as compound value.

For compatibility with previous versions, Test command returns
+CRSL: (0-3)

An enhanced version of Test command has been defined: AT+CRSL=??,
that provides the complete range of values for .

AT+CRSL=??

Enhanced Test command returns the complete range of supported values
for the parameter :

+CRSL: (0-4)

Reference GSM

07.07


+CRSL - Ringer Sound Level

SELINT 1

AT+CRSL[=
]

Set command is used to select the incoming call ringer sound level of the
device.

Parameter:
- ringer sound level
0 - Off
1 - low
2 - middle
3 - high
4 - progressive

Note: if parameter is omitted then the behaviour of Set command is the
same as Read command

AT+CRSL?

Read command reports the current setting of the call ringer in the
format:

+CRSL:

AT+CRSL=?

Test command reports supported values as compound value, in the
format:

+CRSL: (0-4)