beautypg.com

43 cell monitor - #moni – Rainbow Electronics GM862-QUAD-PY User Manual

Page 273

background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 273 of 434

#MSCLASS - Multislot Class Control

SELINT 2


Note: the range for former GM862 family products is 1..8,
excluding class 7.

AT#MSCLASS?

Read command reports the current value of the multislot class in the
format:
#MSCLASS:

AT#MSCLASS=?

Test command reports the range of available values for both parameters
and .

3.5.7.1.43 Cell Monitor - #MONI

#MONI - Cell Monitor

SELINT 0 / 1

AT#MONI[=
[]]

#MONI is both a set and an execution command.

Set command sets one cell out of seven, in a neighbour of the serving cell
including it, from which extract GSM-related information.

Parameter:

0..6 - it is the ordinal number of a cell, in a neighbour of the serving cell

(default 0, serving cell).

7 - it is a special request to obtain GSM-related informations from the

whole set of seven cells in the neighbour of the serving cell.


Note: issuing AT#MONI is the same as issuing the Read command.

Note: issuing AT#MONI= is the same as issuing the command
AT#MONI=0.

AT#MONI?

Execution command reports GSM-related informations for selected cell
and dedicated channel (if exists).

a) When extracting data for the serving cell and the network name is

known the format is:
#MONI: BSIC: RxQual: LAC:
Id: ARFCN: PWR: dBm TA:

b) When the network name is unknown, the format is:

#MONI: Cc: Nc: BSIC: RxQual: LAC:
Id: ARFCN: PWR: dBm TA:

c) When extracting data for an adjacent cell, the format is:

#MONI: Adj Cell [LAC: Id:] ARFCN:
PWR: dBm

where:
- name of network operator