Rainbow Electronics GM862-QUAD-PY User Manual
Page 282

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 282 of 434
#DIALMODE - ATD Dialing Mode
SELINT 0 / 1
1 - (voice call only) OK result code is received only after the called party
answers. Any character typed aborts the call and NO CARRIER result
code is received.
2 - (voice call and data call) the following custom result codes are
received, monitoring step by step the call status:
DIALING (MO in progress)
RINGING (remote ring)
CONNECTED (remote call accepted)
RELEASED (after ATH)
DISCONNECTED (remote hang-up)
Note: The setting is saved in NVM and available on following reboot.
Note: In case a BUSY tone is received and at the same time ATX0 is
enabled ATD will return NO CARRIER instead of DISCONNECTED.
Note: if parameter
same as Read command.
AT#DIALMODE?
Read command returns current ATD dialing mode in the format:
#DIALMODE:
AT#DIALMODE=?
Test command returns the range of values for parameter
#DIALMODE - Dialing Mode
SELINT 2
AT#DIALMODE=
[
Set command sets dialing modality.
Parameter:
ringing (factory default)
1 – (voice call only) OK result code is received only after the called party
answers. Any character typed aborts the call and OK result code is
received.
2 - (voice call and data call) the following custom result codes are
received, monitoring step by step the call status:
DIALING (MO in progress)
RINGING (remote ring)
CONNECTED (remote call accepted)
RELEASED (after ATH)
DISCONNECTED (remote hang-up)
Note: In case a BUSY tone is received and at the same time ATX0 is
enabled ATD will return NO CARRIER instead of DISCONNECTED.
Note: The setting is saved in NVM and available on following reboot.
AT#DIALMODE?
Read command returns current ATD dialing mode in the format: