#MONI - Cell Monitor

SELINT 2

Set command sets one cell out of seven, in a neighbour of the serving cell
including it, from which extract GSM-related information.

Parameter:

0..6 - it is the ordinal number of the cell, in a neighbour of the serving cell

(default 0, serving cell).

7 - it is a special request to obtain GSM-related information from the whole

set of seven cells in the neighbour of the serving cell.


Execution command (AT#MONI) reports GSM-related information for
selected cell and dedicated channel (if exists).

2.

If the last setting done by #MONI is in the range [0..6], the output

format is as follows:

d) When extracting data for the serving cell and the network name is

known the format is:
#MONI: BSIC: RxQual: LAC:
Id: ARFCN: PWR: dBm TA:

e) When the network name is unknown, the format is:

#MONI: Cc: Nc: BSIC: RxQual: LAC:
Id: ARFCN: PWR: dBm TA:

f) When extracting data for an adjacent cell, the format is:

#MONI: Adj Cell [LAC: Id:] ARFCN:
PWR: dBm

where:
- name of network operator
- country code
- network operator code
- progressive number of adjacent cell
- base station identification code
- quality of reception
0..7
- localization area code
- cell identifier
- assigned radio channel
- received signal strength in dBm
- timing advance

Note: TA: is reported only for the serving cell.

3.

If the last setting done by #MONI is 7, the execution command

produces a table-like formatted output, as follows: