+CAMM - Accumulated Call Meter Maximum
SELINT 2
AT+CAMM=
[
[,
Set command sets the Advice of Charge related Accumulated Call Meter
Maximum Value stored in SIM (ACMmax). This value represents the
maximum number of home units allowed to be consumed by the subscriber.
When ACM reaches
Parameter:
home units allowed to be consumed by the subscriber.
is required no more
Note:
AT+CAMM?
Read command reports the ACMmax value stored in SIM in the format:
+CAMM :
where:
ACMmax value in hexadecimal format (e.g. “00001E” indicates
decimal value 30)
AT+CAMM=?
Test command returns the OK result code
Reference GSM
07.07
3.5.4.4.20 Price per Unit and Currency Table - +CPUC
+CPUC - Price Per Unit And Currency Table
SELINT 0 / 1
AT+CPUC[=
Set command sets the values of Advice of Charge related Price per Unit
and Currency Table stored in SIM (PUCT). The PUCT information can be
used to convert the home units (as used in commands +CAOC, +CACM
and +CAMM) into currency units.
Parameters:
DEM etc..); used character set should be the one selected
with command +CSCS.
“1989.27”
required no more
Note: if the parameters are omitted the behavior of Set command is the
same as Read command.
AT+CPUC?
Read command reports the current values of
parameters in the format:
+CACM :