Rainbow Electronics GM862-QUAD-PY User Manual
Page 277

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 277 of 434
#MONI - Cell Monitor
SELINT 2
a.
First row reports the identifying name of the ‘columns’
#MONI: Cell BSIC LAC CellId ARFCN Power C1 C2 TA
RxQual PLMN
b.
Second row reports a complete set of GSM-related
information for the serving cell:
#MONI: S:
c. 3
rd
to 8
th
rows report a reduced set of GSM-related
information for the cells in the neighbours:
#MONI: N
where:
other parameters as before
AT#MONI=?
Test command reports the maximum number of cells, in a neighbour of the
serving cell excluding it, from which we can extract GSM-related
informations, along with the ordinal number of the current selected cell, in
the format:
#MONI: (
and excluding it, from which we can extract GSM-related
informations. This value is always 6.
Example
Set command selects the cell 0
at#moni=0
OK
Execution command reports GSM-related information for
cell 0
at#moni
#MONI: I WIND BSIC:70 RxQual:0 LAC:55FA Id:1D23 ARFCN:736 PWR:-83dbm TA:1
OK
Set command selects the special request to obtain GSM-
related information from the whole set of seven cells in
the neighbour of the serving cell
at#moni=7
OK
Execution command reports the requested information in