AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 221 of 434
+CMGS - Send Message
SELINT 2
D
E
=
1
#
S
M
S
M
O
D
E
=
1
#
S
M
S
M
O
D
E
=
1
#
S
M
S
M
O
D
E
=
1
sending a four character sequence prompt:
After this prompt text can be entered; the entered text should be
formatted as follows:
- if current
alphabet is used and current
03.40 TP-User-Data-Header-Indication is not set, then ME/TA
converts the entered text into GSM alphabet, according to GSM
07.05, Annex A; backspace can be used to delete last character
and carriage returns can be used; after every
user the sequence
the TE.
- if current
coding scheme is used or current
GSM 03.40 TP-User-Data-Header-Indication is set, the entered text
should consist of two IRA character long hexadecimal numbers
which ME/TA converts into 8-bit octet (e.g. the ‘asterisk’ will be
entered as 2A (IRA50 and IRA65) and this will be converted to an
octet with integer value 0x2A)
Note: the DCD signal shall be in ON state while text is entered.
Note: the echoing of entered characters back from the TA is controlled
by echo command E
To send the message issue Ctrl-Z char (0x1A hex).
To exit without sending the message issue ESC char (0x1B hex).
If message is successfully sent to the network, then the result is sent
in the format:
+CMGS:
Reference in integer format.
Note: if message sending fails for some reason, an error code is
reported.
Note: care must be taken to ensure that during the command
execution, which may take several seconds, no other SIM interacting
commands are issued.