SENSOR TEST

Select the SENSOR
TEST Menu

1

Press:

+

+

+

+

The sensor test checks if the
detection sensors operate nor-
mally.

The test items in SENSOR
TEST mode are as follows:

Detection of Top Cover
open/closed status

Detection of Front Cover
open/closed status

Detection of Recording Pa-
per and Recording Paper
Tray presence/absence sta-
tus

NOTE:

When the sensor has bro-
ken, display does not
change next.
But about 40 seconds
passed, it will be set to NG.

Check the Top Cover

2

Open the Top Cover. When its
open state is detected, the
screen below appears. After
checking that the screen is dis-
played, close the Top Cover.

Detects the open state
of the Top Cover.

SENSOR TEST

OPEN TOP COVER

Close the Top
Cover

SENSOR TEST

OPEN FRONT COVER

SENSOR TEST

CLOSE TOP COVER

MENU

If no recording paper is placed
in the Recording Paper Tray,
the screen below is displayed.
You can resume the test by
loading the paper.

SENSOR TEST

PUT IN PAPER

Check the Front
Cover

3

Open the Front Cover. When
its open state is detected, the
screen below appears. After
checking that the screen is dis-
played, close the Front Cover.

Detects the open state
of the Front Cover.

Close the Front
Cover

SENSOR TEST

REMOVE PAPER

SENSOR TEST