Toshiba e-STUDIO 170F User Manual
Page 219
217
Open the Front
Cover
1
Hold the Front Cover by the
grips on both sides of its upper
part and pull it down to open it.
NOTES:
• If a problem with the Re-
cording Unit remains after
this action, you may re-
quire a new Toner Car-
tridge or Drum Unit.
Check for dirt or paper un-
der the Toner Cartridge
and Drum Unit first. Call
your service representa-
tive for assistance.
• Do not pull the Front Cover
too strongly when opening
it.
Recording Unit Cleaning Procedure
When the Recorded Image is not Clear... - continued
Wipe the Paper
Pickup Roller, etc.
3
Wipe the Paper Pickup Roller
with a dry cloth. If the surfaces
require moisture to remove the
dirt, use a cloth slightly damp-
ened with water to remove the
dirt, followed by a dry cloth.
Lift up and holding the green
handle, gently pull out the Pro-
cess Unit.
CAUTION:
Always hold the Process
Unit by the green handle.
Remove the Process
Unit
2
Process Unit
4
Install the Process Unit into
the machine, aligning the
guides of the Unit with the
grooves inside the machine.
Make sure the Process Unit is
inserted inside the machine as
far as it will go.
NOTE:
Pressing in the Process
Unit forcibly could damage
the machine.
Press up the Front Cover until
it clicks to attach securely.
Verify the display has returned
to the Standby Mode.
Close the Front
Cover
5