FUJITSU SPARC M4000 User Manual
Page 352
D-8
SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008
b. Establish a connection through the XSCF-LAN port, and use the XSCF Shell
to check error logs and other information. See
for the corrective
action.
c. Otherwise, check the XSCF event logs and server status by using the XSCF
Shell through the serial port.
Use the following commands to check the events that occurred at the time
the problem occurred:
■
showlogs error
■
showlogs event
■
showlogs power
■
showlogs monitor
■
showlogs console
■
fmdump
If you find an error, see
in this manual for the corrective
action.
d. Check the XSCF console log or panic log for the latest messages. A message
may have been output by the operating system after it detected the
problem. In cases involving a panic, use the showlogs (8) command with
the panic option to check the events that occurred at the time the panic
occurred. For information about using the command, see the
XSCF Reference
Manual.
3. If you cannot find any problem after checking the above points, restart the
system.
4. If you find any problem, see
and take measures based on the
corrective action that is described, such as using the maintenance guidance of
the XSCF Shell command for replacement of the relevant component.