4 connecting to xscf via the serial port, Connecting to xscf via the serial port 3–6, Table 3-3 – FUJITSU SPARC M4000 User Manual
Page 196
3-6
SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008
lists the port numbers used for the DSCP Link and the functions. When
you want to strengthen security of domain side, the following each port must be
permitted to pass packets as necessary.
TABLE 3-3
DSCP Link Port Numbers and Connection Directions for Functions
Port Number /
Protocol
Function
Connection Direction
12/TCP
FMA event translation
XSCF -> Domain
22/TCP
SSH
Domain -> XSCF
24/TCP
FMA event translation
XSCF -> Domain
665/TCP
DR control
XSCF -> Domain
123/UDP
Time synchronization
Domain -> XSCF
3.1.4
Connecting to XSCF via the Serial Port
The following is the procedure for connecting to a terminal to XSCF via the serial
port.
1. Confirm that a serial cable is inserted into the serial connector on the front of
the XSCF Unit, and confirm that the PC and workstation to be used are
correctly connected.
2. Check whether the following are set on the terminal software.
Baud rate: 9600 bps, Data length: 8 bit, No parity, STOP bit: 1 bit,
No flow control, Delay: Except for 0
162/UDP
SNMP Trap function
XSCF -> External network
636/TCP
Authentication with an LDAP server
XSCF -> external network
443/TCP
XSCF Web (https)
External network -> XSCF