Could not connect to xscf through the serial port – FUJITSU SPARC M4000 User Manual
Page 346
D-2
SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008
Could Not Connect to XSCF Through the Serial Port
■
Check the connection between the terminal software and the serial port.
■
Check the settings of the terminal software (baud rate is set to 9600 bps, delay is
set to 0, etc.). For information about the settings, see "Connecting to XSCF via the
serial port" in
.
Could Not Connect Using Telnet to XSCF via the XSCF-LAN
■
Check the LAN cable connection between the XSCF terminal and the server.
■
Check the connection between the terminal software and the telnet port.
■
Use the shownetwork (8) command to check whether the setting for the XSCF-
LAN is enabled.
■
Use the showtelnet (8) command to check whether the setting for telnet is
enabled.
■
Check whether the entered IP address and port number match their settings.
■
Confirm that the number of connections using telnet/SSH does not exceed its
maximum number. For information about the maximum number, see
and
.
■
If necessary, use the console on the personal computer that is directly connected
to XSCF through the serial port to log in to the XSCF Shell, and check the XSCF-
LAN settings by using the shownetwork (8) command.
Could Not Connect Using SSH to XSCF via the XSCF-LAN
■
Check the LAN cable connection between the XSCF terminal and the server.
■
Use the shownetwork (8) command to check whether the setting for the XSCF-
LAN is enabled.
■
Use the showssh (8) command to check whether the setting for SSH is enabled.
■
Check whether the entered IP address and port number match their settings.
■
Confirm that the number of connections using telnet/SSH does not exceed limit.
For information about the limitation, see
■
If necessary, use the console on the personal computer that is directly connected
to XSCF through the serial port to log in to the XSCF Shell, and check the XSCF-
LAN settings using the shownetwork (8) command.
■
Check whether the host key has the correct setting. During XSCF Unit
replacement, the host key setting is restored to the preset key setting of XSCF.
■
Check whether the client software has the correct settings.