FUJITSU SPARC M4000 User Manual
Page 293
Chapter 8 Upgrade of XSCF Firmware and Maintenance
8-23
4. Set the encryption password used for encrypting the output log file.
5. Execute the data transfer. When the data transfer is complete, please contact
authorized service personnel.
Note –
The snapshot menu may be displayed as “Data Collector”.
■
Command operation
1. Connect a USB device to the USB connector mounted on the XSCF Unit front
panel.
2. Perform the snapshot (8) command and specify the local USB device on the
XSCF Unit for the output file (see Note).
XSCF> snapshot -d usb0
3. When the data transfer is complete, please contact authorized service
personnel.
Note –
For details on using the snapshot (8) command, including how to enable
encryption, see the man page or the XSCF Reference Manual.
Saving the Logs to a Specified Target Directory Over a Network
■
Web browser operation
1. Select the snapshot menu for saving the log menu and display the saving
operation page.
2. In the window, select the download button and specify the target directory.
3. Execute the data transfer. When the data transfer is complete, please contact
authorized service personnel.
■
Command operation
1. Perform the snapshot (8) command using a public key, specifying the target
directory, and specifying the encryption password for the output file.
XSCF> snapshot -t [email protected]:/home/joe/logs/x
:
2. When the data transfer is complete, please contact authorized service
personnel.