beautypg.com

Lenovo ThinkServer RD650 User Manual

Page 159

background image

8. Carefully lift the backplane straight up a little bit so that the small hooks

1

on the chassis are aligned

with the corresponding holes in the backplane. Then, move the backplane to the rear of the chassis to
release the backplane from the hooks

1

.

1

Figure 128. Removing the front backplane

9. Touch the static-protective package that contains the new backplane to any unpainted surface on the

outside of the server. Then, remove the new backplane from the package.

Note: Carefully handle the backplane by its edges.

10. Note the orientation of the new backplane. Ensure that the small hooks

1

on the chassis pass through

the corresponding holes in the new backplane. Then, carefully press the new backplane straight down
so that it is secured by the latches

2

on the backplane.

1

2

Figure 129. Installing the front backplane

11. Reinstall all the drives and dummy trays (if any) in the drive bays. See “Installing or replacing a hot-swap

drive” on page 134.

12. Refer to your note to connect the cables to the new backplane.

Chapter 6

.

Replacing hardware

145